Description
Installation REMAC-5
Controller Selection Flow Chart
Controller Selection Table

Description

The REMAC-5 card is designed as a push button or a remote control unit where forward and reverse motion is required. The push buttons can be wired into the terminals provided. Pressing the open button will move the motor in forward direction. Release the button and the motor will stop. If further opening is required then press the button again. Closing is done in the similar manner.

The REMAC-5 has travel timer which is adjustable by trimpot. Option for limit switches is also available. If limit switches are used then a track has to be cut on the button side of the printed circuit board (see wiring diagram).

Installation Instructions REMAC-5

Care should be taken not to cross printed circuit board with 240V wires over or under the board. This would induce spikes onto the sensitive circuitry of the printed circuit board.

 

Wiring Diagram

Power
Connect 240VAC to the 6.3mm connector tabs marked A (for Active) and N (for Neutral).

Motors
Motors should be rated for 240 VAC 10A. The motor should have three wires, i.e. two actives and one neutral. One active is for opening and the other is for closing.

Push Button Inputs
Push button is a normally open contact. When pressed it will start the opening, when released it will stop and when close button is pressed it will start closing and when released it will stop. These push buttons should be waterproof for internal and external use. Waterproofing will prevent false activations, which normally occurs due to moisture inside the button.

Antenna
The antenna connection is used to connect an antenna for the plug in FMR-203. The antenna can be a 50 ohms 27 MHz CB-Antenna or piece of approximately 1 meter of wire.

Limit Switches
The limit switches are normally closed. To use limit switches tracks have to be cut on the bottom side of the PCB (see wiring diagram) and wire to relevant limit switches. Low voltage wiring (24V) can be used for the limit switches.

Remote Control
Remote control is achieved by inserting Elsema’s FMR-203. Power to the REMAC-5 printed circuit board should be switched off during the installation of a receiver. The transmitter is a FMT-302. The transmitter (FMT-302) will have dedicated channels for opening and closing action i.e. Channel 1 when pressed will open the door and when released, will stop. If further opening is required the channel 1 is pressed again. Closing is done in a similar manner using channel 2.

Dimensions
130 X 95 mm