GLR2701
Single Channel 27MHz Gigalink™ Receiver

Features

• Wide supply connection – 11.0 to 28.0 Volts AC/DC
• Highly sensitive receiver input stage. When used with GLT27…. series transmitters and an ANT27L antenna, an operating range of 350 metres (980 ft) is possible.
• Relay Output.
• Crystal controlled for high stability and performance.
• Dual Conversion to reduce interference.
• Uses micro-controller technology that can be re-programmed to suit unique applications.
• Momentary, flip-flop and latching output modes is user selectable.

Applications

• automatic gates, security, timer controlled outputs and simple on/off functions etc


 Click image to enlarge
GLR2701E
Single Channel Enclosed


 Click image to enlarge
Download Datasheet
Programming Instructions

Description
Technical Data
Products in the Range
Block Diagram

 

Description

The GIGALINK™ , GLR2701 is an advanced Remote Control technology available in the world today. GIGALINK™ is an invention that has revolutionised the entire Remote Control technology including Elsema's earlier version of FMT- … and FMR- … series. This state-of-the-art invention brings a new dimension in the world of Remote Control technology in domestic, commercial and industrial applications.

The innovative microcontroller technology replaces the traditional dip switch coding which eliminates any possible code grabbing. Special features such as over four billion code combinations, operational over a wide voltage range, eight user selectable modes and ability to program any number of transmitters to a receiver adds up to the most advanced and secure Remote Control available.

The microcontroller in-built code programming system automatically selects the programming mode that provides flexibility in programming the receiver channel to different transmitter channels. In programming mode the receiver sends a random code to program the transmitter channel. Momentary joining the two CC pins on the receiver board sets the channel to a random code. To program the receiver to the transmitter channel(s) follow the steps outlined in the transmitter instructions.

The receiver power must be connected during code programming.

Dual Crystal Control

The GLR2701 is crystal controlled using dual conversion. Dual conversion is where the received frequency is mixed twice, using a crystal at both mixing stages. This results in less interference, enabling the receiver to operate in noisy industrial applications, improves operating performance, which allows the receiver to pass EMC and stringent radio regulations around the world.

AC/DC Supply, Antenna and Relay Connections

AC/DC power supply, antenna and relay connections are via a six-way screw-type terminal block. Do not connect the supply to the 2.5-mm coding socket since connection may damage the microcontroller.

Different Modes for the Output

Modes are user selectable from the 4-way dip switch, shown below.

4-Way DIP Switch Mode Settings
The output relay will respond in the following manner when receiving the correct signal from a transmitter
"Momentary": Relay on, only while correct signal is received
"Flip-Flop": Relay alternates at every correct incoming signal
"Delayed Off 1": Relay on, but delayed off for 1-10 seconds, adjestable by trimpot
"Delayed Off 2": Relay on, but delayed off for 10-300 seconds, adjustable by trimpot
"Pulsing": Relay will pulse at 1Hz for 10-300 seconds, adjustable by trimpot
"Latching On": Relay will energize until supply to receiver is momentarily interrupted

"On-Off": This mode requires a 2-channel Tx.
Channel 1 will always energize the relay
Channel 2 will always de-energize the relay
To use this mode you need to do channelised code programming. Do not use single code programming.

"On-Off": This mode requires a 4-channel Tx.
Channel 3 will always energize the relay
Channel 4 will always de-energize the relay
(Mode added November 2006)
To use this mode you need to do channelised code programming. Do not use single code programming.

"Test": Relay is energized, for test purpose only

Unique Code System

The microcontroller EEPROM allows large volume users to have a unique code. This enables Elsema to offer everyone “your own” radio control.

Case

The GLR2701 can be supplied with or without a case. The case used to enclose the receiver is Elsema's black UBB plastic case. The receiver can also be inserted to a Quick Mount enabling easy mounting to walls roof etc

Products in the Range

GLR2701
Single Channel
GLR2701240
Single Channel 240V Relay
GLR2702
2-Channel
GLR270312
3-Channel 12V Relay
GLR270324
3-Channel 24V Relay
GLR270412
4-Channel 12V Relay
GLR270424
4-Channel 24V Relay
GLR2708
8-Channel
GLR270812R
8-Channel 12V Relay
GLR270824R
8-Channel 24V Relay
GLR27CS
Single Channel Code Switch
GLR27VOID
Single Channel VOID
GLR2701SS
1-Channel
GLR2702SS
2-Channel

 

Technical Data

Supply Voltage

11.0 to 28 VDC and 10.0 to 28 VAC.
Can use Elsema AC power pack (PP12 or PP24).
Supply lines should be less than 3 metres long to comply with radio frequency authorities.

Current Consumption

10mA standby at 12 VDC Supply
45mA if relay “ON” at 12 VDC Supply

Receiver Type Dual Conversion Superheterodyne
Receiving Freq 27.195MHz (Other freq available on 27.045, 27.145, & 27.455MHz. The 27.455 freq is not available for Australia)
Type of Crystal Used 10.245MHz, Fundamental, 20pf, 30ppm
16.495MHz, Fundamental, 20pf, 30ppm
Operating Temperature Range -5 to 50°C
1st IF Freq 10.7MHz
2nd IF Freq 455kHz
Selectivity -6dB at ±5kHz
-20dB at ±6kHz
Image Rejection At 26.285MHz better than -60dB
Sensitivity 1uV (for output to activate)
Type of Demodulation Narrow-bandwidth Frequency Modulation (FM)
Occupied Bandwidth ±5kHz
Decoding System Microcontroller based 96-bit word
Code Combinations 4,294,967,296
Output Change over relay output, rated at 5 Amps/240 Volts
Connections 6-way screw type terminal block
Antenna 50 ohms, 27MHz CB-Antenna or approximately 1m long & 1mm thick piece of wire
Dimensions 99 x 70 x 20mm
Mounting Hole Size 3.97mm or 5/32"
Weight 77g
Useable Transmitters All Elsema Type 27MHz GLT-... series
Useable Operating Range Up to 350m with proper 50 ohms, 27MHz CB-Antenna. Up to 200m with 1m long antenna wire. Antenna wire should be extended and away from metal. Ranges asume line-of-sight operation.

Block Diagram


GLR2701 12/24 VAC/DC Application


GLR2701 240/110 VAC Application

 


© 2008 Elsema Pty Ltd. All rights reserved.