FMR1510812R, FMR1510824R
Eight-Channel 151MHz Receiver with Relay Outputs

Features

• Wide supply connection – 11.0 to 14.0 Volts AC/DC for FMR1510812R or 21.0 to 28.0 Volts AC/DC for FMR1510824R
• Highly sensitive receiver input stage.
• Eight relay outputs. All outputs can be operated simultaneously.
• Crystal controlled for high stability and performance.
• Uses micro-controller technology that can be re-programmed to suit unique applications.
• Momentary, flip-flop and latching output modes is user-selectable.

Applications

• Pump Control
• Long distance panic button
• On/Off applications in agricultural devices
• Security alarm
• Basic Telemetry eg. Water level indication


 Click image to enlarge

 Click image to enlarge
FMR1510812R
8-Channel, 11-14VAC/DC,
12V Relay Outputs
FMR1510824R
8-Channel, 21-28VAC/DC,
24V Relay Outputs


 Click image to enlarge
Download Datasheet

Description
Products in the Range
Technical Data
Block Diagram

 

Description

FMR15108 can be used in noisy environment and is least affected by electrical interference. This makes FMR15108 an ideal choice for use in heavy industrial environment.

Case

The FMR1510812R, FMR1510824R can be supplied without a case, this allows the receiver to be integrated according to your needs.

The C160 case (weather proof) can be used to enclose the FMR1510812R, FMR1510824R receiver. The receiver with a case is known as FMR1510812RE, FMR1510824RE.

Different Modes for each Output
Modes are user selectable from the 4-way dip switch, shown below.

DIP Switch Mode Settings
The output relay will respond in the following manner when receiving the correct signal from a transmitter
"All Momentary": Relay on, only while correct signal is received
"All Flip-Flop": Outputs alternate at every correct incoming signal
"Momentary & Flip-Flop": Outputs 1-4 are momentary & 5-8 are flip-flop
"Latching on": Outputs will be on until supply to receiver is momentarily interrupted
"Momentary & Flip-Flop": Outputs 1-6 are momentary & 7-8 are flip-flop
"Momentary & Flip-Flop": Outputs 1-2 are momentary & 3-8 are flip-flop
"Momentary & Flip-Flop": Outputs 1-3 are momentary & 4-8 are flip-flop
"Latching on": Output 1 is latching & 2-8 are momentary
"Latching on": Output 1-7 is latching & 8 is momentary.
Mode added on 21/05/07

 

Coding
The 12 way dip switch on the receiver sets the 12 bit unique code for the system.  This has to be matched to that on the transmitter.

Products in the Range


 Click image to enlarge

 Click image to enlarge


 Click image to enlarge


 Click image to enlarge

FMR15101
1-Channel
FMR1502
2-Channel
FMR15101240
1- Channel 240VAC Supply
FMR15102240
2- Channel 240VAC Supply


 Click image to enlarge


 Click image to enlarge

FMR15104
4- Channel
FMR15108
8- Channel
FMR1510824
8-Channel, 12V Supply
FMR1510824
8-Channel, 24V Supply

 

Technical Data

Supply Voltage

FMR1510812R : 11.0 to 14 V AC/DC Absolute maximum DC 18 Volts
FMR1510824R : 21.0 to 28 V AC/DC Absolute maximum DC 35 Volts
Can use Elsema AC power pack (12PP or 24PP )
Supply lines should be less than 3 metres long to comply with radio frequency authorities

Current Consumption

20mA standby, 210mA if all outputs “On”

Receiver Type Single Conversion Superheterodyne
Receiving Freq 151.6MHz (8 selectable frequencies within 150.900 - 151.600MHz with 100KHz spacing avaliable).

Oscillation System

VCO with 10ppm crystal controlled reference oscillator

Operating Temperature Range

-5 to 50°C

IF Frequency

10.7MHz

Selectivity

Better than -6dB at ±25kHz

Type of Demodulation

Narrow-Bandwidth Frequency Modulation (FM)

Occupied Bandwidth

25kHz at -20dB

Relay Contacts

Common (C) Normally Close (NC) and Normally Open (NO)

Output Modes

User selectable from 4-way DIP switch

1

2

3

4

Mode

Description

Off

Off

Off

Off

All Momentary

Outputs on, only while correct signal is received.

On

Off

Off

Off

All Flip- Flop

Outputs alternate at every correct incoming signal.

Off

On

Off

Off

Momentary and Flip-Flop

Outputs 1 to 4 are momentary and 5 to 8 are flip-flop.

On

On

Off

Off

Latching on

Outputs will be on until supply to receiver is momentarily interrupted.

Off

Off

On

Off

Momentary and Flip-Flop

Outputs 1 to 6 are momentary and 7 to 8 are flip-flop

On

Off

On

Off

Momentary and Flip-Flop

Outputs 1 to 2 are momentary and 3 to 8 are flip-flop

Off

On

On

Off

Momentary and Flip-Flop

Outputs 1 to 3 are momentary and 4 to 8 are flip-flop

On

On

On

Off

Latching and Momentary

Output 1 is latching and 2 to 8 momentary

Off

Off

Off

On

Latching and Momentary

Output 1-7 is latching and 8 is momentary

Connection

Supply, Antenna & Outputs - Screw type terminal block

Antenna

50Ω, 151MHz Antenna, Elsema ANT151M for maximum performance
A piece of approximately 1metre wire can be used for short range applications

Microcontroller Can be re-programmed to suit your customised needs

Dimensions

130 x 94 x 42mm

Mounting Hole Size

3.97mm or 5/32”

Weight

240g

Useable Transmitters FMT15101E, FMT15102E, FMT15104E, FMT15108E (with correct setting on the dip switch). See Transmitter datasheet for details.

Useable Operating Range

Up to 5000 metres, depending on installation and type of antenna used. Recommended Antenna is Elsema ANT151M

 

Block Diagram

 


© 2008 Elsema Pty Ltd. All rights reserved.