FMR15102
2 Channel 151MHz Receiver
Features
• Wide supply connection – 11.0 to 28.0 Volts AC/DC
• Highly sensitive receiver input stage.
• Relay Outputs can be operated simultaneously.
• Crystal controlled for high stability and performance.
• Uses micro-controller technology that can be re-programmed to suit unique applications.
• Momentary, flip-flop and latching output modes is user-selectable.
Application
Pump Control
Long distance panic button
On/Off applications in agricultural devices
Security alarm
Basic Telemetry eg. Water level indication
|

Click image to enlarge
Download Datasheet
|
Description
FMR15102 can be used in noisy environment and is least affected by electrical interference. This makes FMR15102 an ideal choice for use in heavy industrial environment.
Modes
1. Momentary Mode
If the dipswitch is off the relay will be in momentary mode.
2. Flip Flop Mode
If the dipswitch is on the relay will be in flipflop mode.
3. Latching
If latching is required (Relay stays on until power is removed) the latching link should be inserted and soldered into the two holes to the left of the 2-way dipswitch and the respective dip switch to be on. Dip Switch 1 will put Channel 1 in latching and Dip switch 2 will put channel 2 in latching mode.
Coding
The 12 way dip switch on the receiver sets the 12 bit unique code for the system. This has to be matched to that on the transmitter.
Apart from the 12 way dip switch there will be an additional dip switch depending upon the receiver type:
- Two channel receiver will have a 2 way dip switch.
This DIP switch on the right side of the 12 way dip switch denotes the channel. See table below.
Generally to use a 2 channel Tx to 2 channel Rx match all the 14 dip switch (12way + 2way just on the right side of the 12 way).
To use a 2 channel Tx to control 2 x single channel receivers, first match the 14 dip switch positions and on the receiver, 15th dip switch OFF is Ch1 and 15th dip switch ON is Ch2.
To use a 2 channel receiver with 2 x single channel transmitters, first match 14 dip switch and then the Tx with Sw15 OFF will activate the Ch1 on the receiver and the Tx with Sw15 ON will activate the Ch2 on the receiver.
FMR15102
2-Way DIP Switch & 2 Relay Output
SW13 |
SW14 |
Relay 1 |
Relay 2 |
OFF |
OFF |
Ch1 |
Ch2 |
OFF |
ON |
Ch3 |
Ch4 |
ON |
OFF |
Ch5 |
Ch6 |
ON |
ON |
Ch7 |
Ch8 |
Products in the Range
Technical Data
Supply Voltage |
11.0 - 28.0 VDC
10.0 - 28.0 VAC
Can use Elsema AC power pack (PP12 / PP24)
Supply lines should be less than 3m long to comply with radio frequency authorities |
Current Consumption |
10mA Standby at 12VDC
63mA if both relay “ON” at 12VDC |
Receiver Type |
Single Conversion Superheterodyne |
Receiving Frequency |
151.6MHz (8 selectable frequencies within 150.900 - 151.600MHz with 100KHz spacing avaliable). |
Oscillation System |
VCO with 10ppm crystal controlled reference oscillator |
Operating Temperature Range |
-5 to 50°C |
IF Frequency |
10.7MHz |
Selectivity |
Better than -6dB at ±25kHz |
Type of Demodulation |
Narrow-Bandwidth Frequency Modulation (FM) |
Occupied Bandwidth |
25kHz at -20dB |
| Output |
Two change over relay outputs, rated at 5 Amps/240 Volts |
Connection |
Supply, Antenna & Outputs - Screw type terminal block |
Antenna |
50Ω, 151MHz Antenna, Elsema ANT151M for maximum performance
A piece of approximately 1metre wire can be used for short range applications |
Dimensions |
95 x 70 x 20mm |
Mounting Hole Size |
3.97mm or 5/32” |
Weight |
83g |
| Useable Transmitters |
FMT15101E, FMT15102E, FMT15104E, FMT15108E (with correct setting on the dip switch). See Transmitter datasheet for details. |
Useable Operating Range |
Up to 5000 metres, depending on installation and type of antenna used. Recommended Antenna is Elsema ANT151M |
Block Diagram

FMR15102 12/24 VAC/DC Application

FMR15102 110/240 VAC Application

|