FMR-240
240V AC Receiver with 240V AC/DC 10A Relay Output

Features

• Crystal Controlled
• Comprising of Receiving, Decoding & Relay-output Sections
• LARGE SCALE INTEGRATED CIRCUIT (LSI) is employed in the decoder section

Applications

• Remote control of garage doors, gates, lights, alarms


 Click image to enlarge
Download Datasheet

Description
Technical Data

Description

The FMR-240 is a crystal controlled single channel receiver, comprising of receiving, decoding and relay-output sections. A specially designed LARGE SCALE INTEGRATED CIRCUIT (LSI) is employed in the decoder section, which ensures operation at low supply voltage, highest reliability, associated with very low power drain.

The receiver works on a digitally encoded 27 MHz frequency modulated (FM) signal. It may be used in applications such as the remote control of garage doors, gates, lights, alarms or in any other new or existing installations where the use of conventional wiring is difficult or impossible to accomplish.

If the code of the input signal (from a transmitter) matches the setting of the coding switch on the receiver (up to 4096 combinations), an output is obtained i.e. the relay operates. This relay provides a clean set of contacts for switching current up to 10 Amps on 240 Volts.

Connection to the receiver is via a five-way screw-type terminal block, with a separate two-way screw-type terminal block for the antenna.

A proper 27 MHz CB-Antenna will give a reliable control range of up to 200 metres, when used with Elsema’s FMT-301, FMT-302, FMT-304 transmitters. If a CB-Antenna is used, the shield of the cable must be connected to the "Sh terminal".

A push Button (designated as "TEST") is provided for relay output testing.

In the momentary mode (MOM) the relay is only activated while the correct signal is received. When changing the slide switch from "MOM" to "FF" (flip/flop mode) the output relay is toggled with every correct incoming signal. This enables the direct use for switching on/off lights etc. In flip/flop mode, the relay always energises at the initial "power-up".

If a "latching-on" output is required, for example receiver is used together with a "Panic Button", a wire link is to be fitted (See picture below). In such a case the relay can only be reset again by momentarily interrupting the supply.

Another feature available is a "delayed-off" output. To facilitate it, a small time unit DU-3 is to be fitted into the four unused holes. When ordering receivers with this function, please specify length of which may be between 1 second to 60 minutes. In this mode the relay energises when a correct code is received or the "TEST" is pushed, and de-energises after the time unit.

Care must be taken, not to bring a receiver near strong magnetic fields, such as DC-Motors, speakers, magnets for reed switches, transformers etc. as it would magnetise the coils and may cause severe de-tuning.

Technical Data
Supply Voltage 240V AC Mains
Current Consumption 14mA 240V AC
Receiving Frequency 27.145MHz (Other freq. available: 27.045, 27.195 & 27.455MHz. NB. 27.455 freq. is not available for Australia )
Type of Crystal Used 26.690MHz, 3rd overtone, 20pF, 30ppm at 0-50°C
IF Freq 455kHz
Selectivity At least -40dB at ±10kHz
Sensitivity Better than 1uV (for relay to switch on)
Type of demodulation Narrow-bandwidth Frequency Modulation (FM)
Band Width ±2.5kHz
Decoding System Onboard 12-way coding switch (4096 digital channels)
Output

Change over relay output
Rated at 10A 240V AC & 10A 30VDC
Approved for 240V AC

Relay Contacts Common (C) Normally Close (NC) and Normally Open (NO)
Connections Supply & Relay Contacts: 5-way screw type terminal block (Rated 240VAC)
Antenna: 2-way screw type terminal block
Antenna 50 ohms, 27MHz CB-Antenna or approximately 300mm long wire for short range applications.
Dimensions 130 x 70 x 37mm
Weight 128g
Compatible Transmitters FMT-... series

 


© 2008 Elsema Pty Ltd. All rights reserved.